Excess Flow Valves Explained

Excess flow valves explained: working principle and applications

 

The Hazards of Line Ruptures in Fluid Systems

 

 

Modern industrial operations involve complex working conditions. Fluid systems serve as critical components in industrial processes, responsible for media transportation, pressure regulation, and closed-loop process control. Any failure in these systems can significantly disrupt production and potentially lead to serious safety incidents. Therefore, failure prevention and emergency response are among the most critical considerations in process design and equipment selection.

 

Line rupture is one of the most serious failures that can occur during fluid transportation. When a pipeline ruptures, the downstream flow rate can increase dramatically, causing pressure throughout the fluid system to run out of control and affecting the upstream pipeline. These uncontrolled pressure fluctuations can place considerable stress on various fluid system components, damaging valves, instruments, and other equipment. Such damage, or even equipment failure, can further complicate troubleshooting.

 

To address line rupture risks, some manufacturers install block valves at vulnerable points in pipelines. However, conventional valves may not respond reliably to sudden changes in pressure and flow conditions. Furthermore, relying on manual intervention to shut off the flow cannot meet the rapid response requirements of emergency situations.

 

To address the risk of downstream line ruptures, FITOK recommends installing excess flow valves at appropriate locations. An excess flow valve is one of the most suitable solutions for automatically preventing and responding to line ruptures and sudden increases in flow rate.

 

How Does an Excess Flow Valve Respond to a Downstream Line Rupture?

 

 

Excess flow valves are designed to ensure flow safety within fluid systems. Their internal structure is illustrated in Figure 1.

 

An excess flow valve contains a spring-loaded poppet. Under normal operating conditions, the poppet remains in the open position, allowing the medium to flow through the valve.

 

When a downstream failure causes a sudden increase in flow rate that reaches the valve's trip threshold, the downstream pressure drops rapidly, increasing the pressure differential between the upstream and downstream sides. Meanwhile, the increased flow velocity generates an impact force. The combined effect of these two forces drives the poppet rapidly into the tripped position. The valve then trips, helping prevent uncontrolled discharge of the medium.

 

Once the downstream fault has been resolved, the pressure upstream and downstream of the valve equalizes through the bleed vent in the poppet. The spring then pushes the poppet back to its original open position, automatically resetting the excess flow valve.

 

Compared with conventional manually operated valves, excess flow valves automatically detect changes in flow rate and respond accordingly. They do not require manual intervention and can automatically trip when a fault occurs, then reset themselves once the fault has been resolved.

 

Working principle of an excess flow valve

Figure 1. Working Principle of an Excess Flow Valve

 

Typical Applications of Excess Flow Valves

 

 

Application in Gas Pipelines

Excess flow valve application in a gas pipeline

Figure 2. Excess Flow Valve Application in Gas Pipelines

Installing excess flow valves in gas pipelines helps prevent large-scale gas leaks caused by downstream pipeline damage resulting from various external factors.

Application on Gas Cylinders

Excess flow valve application at a gas cylinder outlet

Figure 3. Excess Flow Valve Application on Gas Cylinders

Installing excess flow valves at gas cylinder outlets helps prevent significant gas loss caused by accidental leakage.

 

Why Choose FITOK EV Series Excess Flow Valves?

 

 

1. More Spring Options

The FITOK EV Series offers three spring options, providing a wider selection of trip flow rates to accommodate different working conditions.

2. More O-Ring Material Options

FITOK offers excess flow valves with O-rings made from various materials. These materials are suitable for different temperature ranges and media, allowing the valves to accommodate a wide range of working conditions.

3. Easy-to-Identify Appearance

To distinguish excess flow valves from other valves with similar appearances and help operators identify them quickly during troubleshooting, FITOK uses green as the distinctive visual marking for its EV Series excess flow valves.

 

Important Considerations When Selecting and Using Excess Flow Valves

 

 

Q

Can an Excess Flow Valve Be Used to Open and Close a Flow Path?

No. To allow upstream and downstream pressures to equalize and enable automatic resetting, excess flow valves are generally designed with a bleed vent. This vent remains open at all times. As a result, a small amount of medium can continue to pass through the valve even when it is in the tripped position.

 

Q

What Is the Difference Between Excess Flow Valves, Flow Switches, and Check Valves?

Excess flow valves, flow switches, and certain check valves may have similar appearances, structural features, or working principles. This can sometimes cause confusion among customers. The following table compares the key characteristics of these three types of products.

 

 
Comparison Excess Flow Valve Flow Switch Check Valve
Design function Prevents excessive flow Indicates excessive flow Prevents reverse flow
Key difference Shuts off forward flow when the flow rate becomes excessive Generates a signal when the flow rate becomes excessive but has virtually no effect on the flow itself Allows forward flow and shuts off reverse flow
Typical application Gas pipelines and gas cylinder outlets System monitoring and alarms; only available for gas applications Pump outlets and compressor outlets
Typical appearance FITOK EV Series excess flow valve FITOK EV Series FITOK FV Series flow switch FITOK FV Series FITOK CV Series check valve FITOK CV Series
Table 1. Comparison of Excess Flow Valves, Flow Switches, and Check Valves

 

Q

How Should an Excess Flow Valve Be Installed?

Excess flow valves are generally used to prevent and respond to downstream line ruptures. When a downstream pipeline ruptures, the excess flow valve detects the resulting change in flow rate and responds accordingly. However, the valve has a limited sensing distance. If the rupture occurs too far from the valve, it may not respond in time. Therefore, it is recommended that potential pipeline damage points be identified in advance and that excess flow valves be installed upstream of these vulnerable locations, as close to them as practicable. Although the excess flow valve has no requirements for vertical or horizontal installation, they have strict flow-direction requirements. Always follow the flow-direction arrow marked on the valve body when installing the valve.

 

For more information, please visit the FITOK official website. Should you have any questions, please leave a message. Our team will get back to you promptly.